چکیده: 

The use of Cold Thermal energy storage systems (CTES) is to decrease power consumption in air conditioning systems. CTES systems have 2 types full operating mode (FOM) and partial operating mode (POM). Objective functions are considered as exergy efficiency and total annual cost because of releasing co2 of CTES systems. Multi-objective techniques are used in MOPSO and SEAP2 algorithm to optimize target functions. The fidings achieved from multi-objective analysis indicate a difference in the optimal amounts of design points compared to single- objective optimization, objective function 1 (exergy efficiency) and objective function2 (total annual costs). Also the report of studying this model represent that because of the use of CTES, there is reduction of electricity consumption. Also because of transferring cooling load from peak hours to low consumption and reduced power consumption, we have a reduction in operating costs comparing to a traditional air conditioning system. Finally, the results show that the payback period for an CTES system in partial storage mode is 3.43 years and for a full storage system is close to 3.88 years, however, due to further reduction of operating costs in full storage mode, the total stored cost of this system after the useful life of the set (15 years) is more than partial storage type. it should be noted that the use of the CTES system decreases the production of CO2, which reduces environmental pollution. Finally, the PCMs used in the construction industry are introduced and compared with each other in terms of exergy efficiency.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 40

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1380
  • دوره: 

    13
  • شماره: 

    2
  • صفحات: 

    21-32
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    929
  • دانلود: 

    174
چکیده: 

در این مقاله، بازگشت ناپذیری در یک سیستم ذخیره کننده حرارتی مورد بررسی قرار گرفته است. سیستم از دو استوانه هم محور تشکیل شده است. سیال عامل در استوانه داخلی جریان دارد و استوانه خارجی از ماده ذخیره کننده پر شده است. نحوه کار سیستم به صورت تناوبی می باشد. معادلات دیفرانسیل حاکم بر انتقال حرارت در سیال، دیواره و محیط ذخیره کننده به صورت عددی حل شده اند. پس از انجام یک سری کارهای آزمایشگاهی و کسب اطمینان از صحت نتایج عددی بدست آمده، تاثیر عوامل مختلف بر بازگشت ناپذیری سیستم مورد بررسی قرار گرفته است. نتایج نشان می دهد که نسبتهای هندسی ذخیره کننده تاثیر زیادی بر بازگشت ناپذیری دارد. همچنین، تعداد سیکلهای لازم برای رسیدن به سیکل پایدار با بازگشت ناپذیری در ذخیره کننده نسبت مستقیم دارد. سرانجام، پیشنهادهایی برای کاهش بازگشت ناپذیری در راستای بهینه کردن یک سیستم ذخیره کننده حرارتی ارایه شده است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 929

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 174 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1397
  • دوره: 

    48
  • شماره: 

    1 (پیاپی 82)
  • صفحات: 

    159-167
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    591
  • دانلود: 

    209
چکیده: 

در این تحقیق امکان افزایش کارایی سیستم خنک کننده تبخیری مستقیم با استفاده از تلفیق آن با یک مخزن آب ذخیره کننده انرژی سرمایشی مورد مطالعه قرار گرفته است. آب درون این مخزن، در طی ساعات شب، سرما را در خود ذخیره کرده و از آن در طول ساعات روز جهت کاهش دمای هوای خروجی از کولر استفاده می شود. در این مقاله، ابتدا معادلات حاکم بر سیستم تبخیرکننده تلفیقی فوق الذکر استخراج شده اند و سپس در ادامه، اثر جرم آب درون مخزن بر مشخصات هوای خروجی از کولر تبخیری، مورد بررسی قرار گرفته است. نتایج بیانگر این موضوع است که در شرایط نمونه استفاده از مخزن آب ذخیره کننده انرژی سرمایشی با جرمی معادل با سه برابر جرم هوای خشک ورودی به کولر در یک ساعت، سبب کاهش دمای هوای خروجی از کولر به میزان ° C2. 02 در ساعت 14: 00 خواهد شد. انتقال ساعات بیشینه و کمینه دمای هوای خروجی از کولر به ساعات دیگر و همچنین کاهش دامنه تغییرات هوای خروجی از سیستم از حدود ° C6 به حدود ° C3. 5، مهم ترین مزایای سیستم تلفیقی پیشنهادی فوق الذکر است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 591

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 209 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    1401
  • دوره: 

    9
  • شماره: 

    2
  • صفحات: 

    130-140
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    119
  • دانلود: 

    27
چکیده: 

انرژی حرارتی خورشیدی منبع فراوان و بی­نظیر تجدیدپذیر است که اگر با واحدهای ذخیره­سازی ترکیب شود به عنوان گزینه­ای جذاب و قابل رقابت با تجهیزات متعارف مطرح می­شود. سیستم ذخیره­سازی بستر متراکم (PBSS) یکی از روش­های ذخیرۀ انرژی گرمایی خورشیدی است که به دلیل سادگی و مقرون به­صرفه بودن، برای کاربردهای گرمایش گلخانه­ها، خشک­کردن محصول و گرمایش فضا استفاده می­شود. در این مطالعه پارامترهای تاثیرگذار بر عملکرد PBSSها و پارامترهای استفاده شده برای ارزیابی عملکرد آن ها شرح داده شده­اند. در ادامه به ارزیابی اقتصادی و برخی از کاربردهای PBSS پرداخته شده است. از میان دو نوع بستر ثابت و بستر سیال، اگرچه سیستم های بستر سیال نرخ های بالاتری از انتقال گرما و جرم را ارائه می کنند اما مشکلات فنی بیشتری در طراحی و ساخت دارند. از میان دو نوع جریان شعاعی و جریان محوری، سیستم شعاعی می­تواند بازدهی مشابه سیستم محوری را با هزینه بیشتر بدست آورد. از میان مواد جامد مورد استفاده در بستر ثابت، چدن بالاترین سطح چگالی انرژی را داراست، اما سنگریزه­ها به دلیل دوره برگشت هزینه کمتر نسبت به چدن، توصیه می­شوند. برخی مقالات، عملکرد ماسه را از بقیه مواد بهتر دانستند. هندسه مستطیلی برای سطح مقطع مخزن ذخیره­سازی کمترین هزینه واحد ذخیره­سازی را دارد، اما افت فشار زیادی را به علت اثرات گوشه­ای ایجاد می­کند. در یک مطالعه که از PBSS برای کشت گلخانه­ای در طول شب استفاده کردند، به این نتیجه رسیده­اند که اگر سیستم سه ماه در سال کار کند، دوره بازپرداخت هزینه پنج سال خواهد بود.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 119

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 27 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1394
  • دوره: 

    31-3
  • شماره: 

    2 (ویژه مهندسی مکانیک)
  • صفحات: 

    33-39
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1259
  • دانلود: 

    283
چکیده: 

نیاز روز افزون بشر به انرژی، محدودیت منابع انرژی، آلودگی هوا بر اثر انتشار گازهای آلاینده ناشی از احتراق سوخت های فسیلی، و گرم شدن زمین همگی از مواردی هستند که صرفه جویی و مصرف بهینه انرژی را اجتناب ناپذیر می کنند. یکی از راه های پیش رو خیره سازی انرژی در دسترس و استفاده از آن در مواقع مورد نیاز است. ذخیره سازی سرمای شب و استفاده از آن برای تهویه هوای روز در مناطق کویری که اختلاف دمای شب و روز قابل ملاحظه است، در کنار سیستم های تهویه متداول و پرمصرف یا به جای آن، یکی از فرصت های صرفه جویی در مصرف انرژی است. در این پژوهش یک مدل یک بعدی برای حل یک سامانه ریژنراتور بستر ثابت حاوی پلی اتیلن گلیکول 600 به عنوان ماده تغییر فاز ارائه، و نتایج حاصل از حل آن با نتایج آزمایشگاهی مقایسه شده است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1259

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 283 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

Esmaeili Shayan M. | Hayati M.R.

اطلاعات دوره: 
  • سال: 

    2023
  • دوره: 

    14
  • شماره: 

    1
  • صفحات: 

    17-25
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    26
  • دانلود: 

    0
چکیده: 

Having kilometers of asphalt road, yet with this heat going to waste, an attempt has been made in this research to extract the road's renewable energy heat. The purpose of the experiment is to compare the energy and exergy efficiency of various materials of asphalt solar water heaters (ASWH), as well as heat transmission through the water tube and how friction affects exergy destruction. The water flow rate of one ASWH was 0.01 kg/s, while that of the other was 0.02 kg/s. Each ASWH has an area of 0.5 square meters. The copper tube is buried 10 mm deep in the asphalt. 15 degrees is the angle of inclination. The results indicate that the energy and exergy efficiencies are reasonably high for the water flow rate of 0.02 kg/s. Depending on the water flow rate, asphalt temperature, and sunlight intensity, the energy and exergy efficiencies changed from 32% to 65% and 5.8% to 16%, respectively. The water flow rate is an essential parameter for estimating the internal convective heat transfer coefficient and Reynolds number in order to calculate the friction factor in the copper tube based on internal convection heat transfer. In contrast, the friction factor is a consequence of the pressure loss and exergy degradation induced by friction.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 26

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    1398
  • دوره: 

    50
  • شماره: 

    2
  • صفحات: 

    319-329
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1506
  • دانلود: 

    513
چکیده: 

امروزه اهمیت استفاده از انرژی های تجدیدپذیر بر کسی پوشیده نیست. در میان انواع انرژی های تجدیدپذیر، انرژی خورشیدی، بیشترین کاربرد را به خود اختصاص داده است. اما جمع کننده های خورشیدی در شب و یا هوای ابری کارآیی خود را از دست می دهند. ذخیره سازی گرمای نهان توسط مواد تغییر فاز دهنده (PCMs) می تواند به عنوان یک راه حل برای مشکل فوق به کار گرفته شود. اما اکثر PCMها، دارای ضریب هدایت حرارتی پایینی هستند. در این پژوهش برای حل این مسئله، از فناوری نانو بهره گرفته شده است. از پارافین واکس به عنوان PCM و از نانوذره اکسید آلومینیوم (Al2O3) و نانوذره مس (Cu) جهت ارتقاء خواص حرارتی آن به عنوان مواد نانوساختار استفاده شدند. خواص ساختاری نانوکامپوزیت های ساخته شده با میکروسکوپ الکترونی روبشی نشر میدانی مطالعه شدند. آزمایش ها با آزمون فاکتوریل در قالب طرح کاملاً تصادفی با 3 عامل اصلی، شامل درصد وزنی نانوذره (در 3 سطح)، نوع نانوذره (در 2 سطح) و اندازه قطر متوسط نانوذره (در 3 سطح) و همچنین پارافین واکس خالص به عنوان نمونه شاهد، با 3 تکرار انجام شده است. ضریب هدایت حرارتی به عنوان مهم ترین پارامتر تأثیرگذار بر انتقال حرارت نانوسیالات و PCMها، در یک گستره دمایی برای هر نمونه و در فاز جامد اندازه گیری شد. بیشترین و کمترین مقدار آن نسبت به نمونه شاهد به ترتیب 442% و 122% افزایش داشته است. تجزیه واریانس داده ها نشان داد اثر اندازه، نوع و غلظت نانوذره آمیخته شده در PCM، بر این ضریب در سطح 1% معنی دار است، همچنین در اندازه های مختلف نانوذرات، با افزایش غلظت، مقدار آن افزایش می یابد و در اندازه های کوچک تر، ضریب هدایت حرارتی بهتری مشاهده شد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1506

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 513 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    2022
  • دوره: 

    41
  • شماره: 

    10
  • صفحات: 

    3304-3313
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    27
  • دانلود: 

    0
چکیده: 

Phase Change Materials (PCMs) can be used as Thermal energy storage systems in the form of latent heat. These materials are commonly enclosed in a suitable container, in order to prevent leakage of the molten PCM into the surrounding environment. In this study, palmitic acid and polyaniline were used as PCM and polymeric shell, respectively, to prepare a form stable composite. SiO2 nanoparticle was added to the composite to improve the Thermal characteristics of the composite. The structure and morphology of the prepared form stable nanocomposite were investigated by Fourier Transform InfraRed (FT-IR) spectroscopy, Field Emission Scanning Electron Microscopy (FE-SEM), and X-Ray Diffract meter (XRD) tests. It was found that the synthesized nanocomposite was fabricated in the form of relatively smooth and compact spherical particles with a size of about 500 nm. Thermal properties of the prepared nanocomposite containing different concentrations of SiO2 nanoparticles were determined using Differential Scanning Calorimetry (DSC) and Thermo Gravimetric Analysis (TGA) tests. It was found that the melting temperature and Thermal conductivity of the polyaniline/palmitic acid composite increased by about 16% and 62%, respectively, when combined with 2 wt. % SiO2 nanoparticles. The obtained results revealed that the polyaniline/palmitic acid/2 wt. % SiO2 nanocomposite can be considered a suitable option for Thermal energy storage applications.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 27

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1397
  • دوره: 

    48
  • شماره: 

    1 (پیاپی 82)
  • صفحات: 

    297-306
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    583
  • دانلود: 

    260
چکیده: 

ماهیت تناوبی انرژی خورشیدی از مهمترین مشکلات این نوع انرژی به شمار می آید. در این راستا، یک سیستم ذخیره سازی انرژی گرمایی کارآمد می تواند در افزایش بهره وری یک نیروگاه خورشیدی بسیار موثر باشد. در این مقاله، چندین چیدمان مختلف برای مبادله کن گرمایی فوق گرمایش بخار برای ذخیره سازی انرژی گرمایی بر اساس مواد تغییر فاز دهنده به صورت عددی شبیه سازی شده، سپس بر اساس قانون دوم ترمودینامیک مورد ارزیابی قرار گرفته است تا مناسب ترین چیدمان مشخص شود. همچنین عملکرد یک سیستم ذخیره سازی انرژی بتنی با سیستم های دیگر مقایسه شده است. نتایج به دست آمده نشان می دهد با افزایش تعداد ماژول های ماده تغییر فاز دهنده از یک تا سه عدد، میزان بازگشت ناپذیری کاهش می یابد و راندمان سیستم یک تا سه درصد افزایش می یابد. همچنین افزایش تعداد ماژول ها باعث کاهش گرادیان دمای خروجی می شود. نتایج بررسی تاثیر دبی و دمای ورودی بخار نشان می دهد با افزایش این دو پارامتر راندمان اگزرژی سیستم کاهش می یابد. با افزایش پنج برابری دبی ورودی و یا افزایش بیست درجه‍ ای دمای بخار ورودی حین زمان شارژ سیستم ذخیره انرژی، راندمان سیستم تقریبا پنج درصد کاهش می یابد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 583

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 260 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

MIRAHMAD A. | SADRAMELI S.M. | Jamekhorshid A.

اطلاعات دوره: 
  • سال: 

    2016
  • دوره: 

    13
  • شماره: 

    2
  • صفحات: 

    33-45
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    444
  • دانلود: 

    0
چکیده: 

energy crisis is a major challenge in the current world. Latent heat Thermal energy storage (LHTES) systems are known as equipment with promising performance by which Thermal energy can be recovered. In the present study a comprehensive theoretical and experimental investigation is performed on a LHTES system containing PEG1000 as phase change material (PCM). Discussed topics can be categorized in three parts. At first, a one dimensional mathematical model is introduced for a heat exchanger containing flat slabs of PCM. To consider the latent heat of phase change, effective heat capacity is used in the model. Secondly, through eight experiments designed by using factorial method, effects of inlet air velocity and temperature on the outlet stream is investigated. The results proved that having a determined temperature difference between inlet air and the PCM in both hot and Cold cycles can enhance the efficiency. Finally, the feasible applications of a LHTES system for controlling the temperature swing in a greenhouse is studied numerically and the results are compared with experimental values. As a result, by using this passive coolant system diurnal internal temperature can be reduced for 10°C.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 444

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button